Search found 455 matches

by jry
Mon Mar 11, 2024 5:04 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Motorola R26xx secret menu access?
Replies: 3
Views: 93

Re: Motorola R26xx secret menu access?

in previous firmware that was the alignment screens for the CRT
by jry
Mon Mar 11, 2024 5:03 am
Forum: APX Series Subscribers
Topic: APX 6000 Won't get a GPS lock
Replies: 2
Views: 174

Re: APX 6000 Won't get a GPS lock

well the firmware update is a mistake,

I would stay below 29.XX ....never go to the latest

You may have now locked in any issues due to the flash code ....oh well
by jry
Sun Feb 18, 2024 10:51 am
Forum: General Motorola Solutions & Legacy Radio Discussion
Topic: MAXTRAC Cross Band VHF -UHF Repeater
Replies: 2
Views: 270

Re: MAXTRAC Cross Band VHF -UHF Repeater

of course you may have to program the connector to provide the needed functions and pin assignments.
by jry
Sat Jan 27, 2024 7:43 am
Forum: General Motorola Solutions & Legacy Radio Discussion
Topic: Oddball multi-channel alert monitor
Replies: 5
Views: 677

Re: Oddball multi-channel alert monitor

I suspect that the add on board is a whole five freq front end ...the main board channel 1 and front end are enabled with the SIMUL button with 2 -6 being selected for the secondary. In order to add just five channels you wouldn't need that much HW. The SIMUL button probably just grounds chan 1 all ...
by jry
Tue Jan 16, 2024 6:29 pm
Forum: Test Equipment & RF Equipment Alignment
Topic: Motorola R2200A and R2001D calibration service
Replies: 2
Views: 590

Re: Motorola R2200A and R2001D calibration service

The R2001D may be worth the cost ....doubt the 2200 is worth it from a commercial value perspective. The shipping cost alone any more would exceed the value IMHO You would be better to invest in a GPS based reference for the frequency and standard deviation null for FM. Output level I would get a de...
by jry
Tue Jan 16, 2024 6:23 pm
Forum: ASTRO25 Series (XTS/XTL 1500/2500/5000) Subscribers
Topic: Different Vocon board revisions?
Replies: 1
Views: 273

Re: Different Vocon board revisions?

not that I am aware ...interchanged them as needed
by jry
Thu Dec 28, 2023 6:34 am
Forum: General Motorola Solutions & Legacy Radio Discussion
Topic: SYSTEMS 9000 CONTROL HEADS
Replies: 11
Views: 1483

Re: SYSTEMS 9000 CONTROL HEADS

do you have an older analog spectra or an Astro Spectra ? None of those heads will work on an Astro Spectra ...you may be able to update the firmware in the 1063 head to work though the 1033 head is the older 9000 series only the 1047 and 1063 should work on an old spectra if it is an A9 version radio
by jry
Tue Nov 14, 2023 3:24 pm
Forum: ASTRO Series (Astro Saber, Spectra, XTS3000/3500) Subscribers
Topic: Astro Saber Programing
Replies: 2
Views: 338

Re: Astro Saber Programing

original astro saber will not work unless you use a 25-25 pin adapter that flips the two data lines
by jry
Sun Nov 05, 2023 6:11 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Motorola R2670 : KVL
Replies: 2
Views: 481

Re: Motorola R2670 : KVL

The RTL4200A has the same connector

From the notch at 12oClock lets say pin 1 is the first pin on the right

1 = GND
2 = KEY
3 = KID
4 = WE

copied from a post on the Communications Support forum
by jry
Tue Oct 24, 2023 6:26 pm
Forum: ASTRO Series (Astro Saber, Spectra, XTS3000/3500) Subscribers
Topic: XTS3000 Question
Replies: 2
Views: 358

Re: XTS3000 Question

common issue ...ASK is a HW key ...USB

there was some posts about editing the SREC /bin file to remove years back. ASK location seemed somewhat dynamic as well ...location different depending on versions.

Usually easier to just over write with a new codeplug
by jry
Wed Mar 29, 2023 6:40 am
Forum: APX Series Subscribers
Topic: APX7000 won't turn on
Replies: 2
Views: 979

Re: APX7000 won't turn on

I thought I had just sent one through the depot last summer but they may have been dropped since then. Regardless I would try to clip an external current limited supply onto the battery contacts ...the negative can go to the chassis. Set the voltage to 7.5 and the current fully limited /zero and the...
by jry
Fri Jan 27, 2023 6:08 am
Forum: Test Equipment & RF Equipment Alignment
Topic: IFR2975 Generator/Power Term investigation
Replies: 1
Views: 708

Re: IFR2975 Generator/Power Term investigation

there are multiple items that often fail on the 2975 at the same time especially around the GEN and Receive. I very rarely get a 2975 through calibration that does not have issues ...like 60 -70% have one or more items need repair. This is often the case with service monitors that are complex device...
by jry
Fri Jan 20, 2023 6:19 am
Forum: Test Equipment & RF Equipment Alignment
Topic: IFR 1600S Only Beeping
Replies: 6
Views: 2890

Re: IFR 1600S Only Beeping

replace the caps on the power supply filter board. 1. pull power supply ....two screws on side , two captive by the connectors , remove power supply connectors. you may have to remove the CRT connector and fuse holders to get the clearance for it to pull out. 2. remove the screws around the bottom p...
by jry
Thu Nov 03, 2022 6:30 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Rotary encoder for IFR 2975?
Replies: 1
Views: 926

Re: Rotary encoder for IFR 2975?

the rotary encoder skipping seems to be more of a software issue than hardware. doubt that replacing would help because I have seen that in most units ...not sure if it's more prevalent in the 200 Mhz processors or not. The up arrows do seem to be more consistent vs. the rotary control I usually fin...
by jry
Mon Jun 27, 2022 5:56 am
Forum: Test Equipment & RF Equipment Alignment
Topic: R2001C RF output has a DC voltage?
Replies: 1
Views: 2261

Re: R2001C RF output has a DC voltage?

sounds like one of the components in the RF I/O has some leakage. The R2001C had an odd RF I/O design. Part of which was a diode switch path in parallel with the RF relay. It's like they didn't believe the relay to engage the 50 ohm termination would be fast enough so they added an diode RF switch. ...
by jry
Mon Apr 25, 2022 4:27 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Com120B deviation meter selftest fail
Replies: 1
Views: 1809

Re: Com120B deviation meter selftest fail

the COM-120 loops back using the RF path in the power termination assembly for the various tests. The problem may be the RF section specifically the synthesizer sections not locking at the specific frequency used during the self test. Usually its the 1st LO modules that have issues ...there are two ...
by jry
Wed Mar 23, 2022 2:58 pm
Forum: Test Equipment & RF Equipment Alignment
Topic: Antenna connector for R2400?
Replies: 5
Views: 2612

Re: Antenna connector for R2400?

these are the fused front panel BNC connectors. A portion of the BNC unscrews and a 1/16 amp pico fuse is inside.
newer designs avoid using these fuses and have a more sophisticated approach to over power situations on RF ports.
by jry
Mon Mar 21, 2022 5:34 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Antenna connector for R2400?
Replies: 5
Views: 2612

Re: Antenna connector for R2400?

finding new may be tough. closest is a JFW BNC inline fuse. Pasternack used to have one @ 75.00 each. best bet is to either 1. repair the damaged connector 2. salvage one from a scrap Motorola service monitor ...used on the R20XX, R22XX , R24XX and R26XX series. 3. Bypass and just use a jumper solde...
by jry
Sat Jan 22, 2022 5:29 am
Forum: APX Series Subscribers
Topic: XTL to APX
Replies: 4
Views: 3385

Re: XTL to APX

APX mobile has channel voice announcements , multi band , GPS and support of newer heads In emergency vehicles voice announcements has a lot of value in operating the radio without looking at the head to see if you are on the correct channel. If that has no value than there really isn't much differe...
by jry
Tue Dec 28, 2021 10:59 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Ramsey Com3010 Service Monitor Password
Replies: 8
Views: 4205

Re: Ramsey Com3010 Service Monitor Password

given that's it's still sold and supported they should offer calibration for it at a price inline with the cost of the unit. I'm sure that unit has a fit in the market place ...like an IFR 500A equivalent/upgrade ....but would not be my first choice as a primary service monitor. surprised that it's ...
by jry
Sun Dec 26, 2021 10:14 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Ramsey Com3010 Service Monitor Password
Replies: 8
Views: 4205

Re: Ramsey Com3010 Service Monitor Password

so I stand corrected the 3010 version has a "tuned" power meter ...see page 37 on the users manual. Who knew 8) You can enter the TX frequency or have it detect it by looping the -30 port on the back to the RF in. See the manual for details. Those measured power values are too far out to b...
by jry
Sat Dec 25, 2021 6:25 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Ramsey Com3010 Service Monitor Password
Replies: 8
Views: 4205

Re: Ramsey Com3010 Service Monitor Password

The COM3010 like most vintage service monitors uses a broadband power measurement approach and not tuned or compensated to the specific operating frequency. Also there are tolerances on the power meter measurements as well and in this case it's .5db so depending on the actual power in 1Watt off may ...
by jry
Mon Oct 18, 2021 8:09 am
Forum: Base Stations, Repeaters, General Infrastructure
Topic: Quantar won't startup
Replies: 12
Views: 10690

Re: Quantar won't startup

surprised the R1 and R2 exciter and PA didn't interoperate .

Usually an R2 exciter would program down into the 140's and a R2 PA cover down into that range as well.

May have been that the PA was defective and not really a R1 R2 issue
by jry
Thu May 20, 2021 7:20 am
Forum: ASTRO Series (Astro Saber, Spectra, XTS3000/3500) Subscribers
Topic: Astro Spectra CPS
Replies: 8
Views: 7529

Re: Astro Spectra CPS

cheapest cable is a direct RS-232 to the rear 15 pin connector.

by default the controller is jumpered for RS-232 but the jumpers can also be moved to support a VRS

The programming cable for the W series microphone connector are typically rare and expensive.
by jry
Wed May 19, 2021 11:06 am
Forum: ASTRO Series (Astro Saber, Spectra, XTS3000/3500) Subscribers
Topic: Astro Spectra CPS
Replies: 8
Views: 7529

Re: Astro Spectra CPS

the reason I mention that is if the radio doesn't have a tag it may be an analog version. normally you would get a codeplug too new error if this was a version issue. Pull the top cover and see which controller is installed. It may also be an Astro Spectra Plus which also uses a different CPS ....us...
by jry
Wed May 19, 2021 11:02 am
Forum: ASTRO Series (Astro Saber, Spectra, XTS3000/3500) Subscribers
Topic: Astro Spectra CPS
Replies: 8
Views: 7529

Re: Astro Spectra CPS

there is a different CPS for the Astro Spectra vs. the older analog only Spectra's
by jry
Fri May 07, 2021 6:46 am
Forum: ASTRO Series (Astro Saber, Spectra, XTS3000/3500) Subscribers
Topic: XTS3000 strange issue: This radio is NOT FLASHportable!!
Replies: 11
Views: 7942

Re: XTS3000 strange issue: This radio is NOT FLASHportable!!

the D version smartrib is only required for the 800 P25 trunking version firmware.

The standard non P25 trunking firmware will flash fine ...which is used everywhere else..like VHF and UHF which never supported P25 trunking.
by jry
Fri Apr 30, 2021 9:20 am
Forum: ASTRO Series (Astro Saber, Spectra, XTS3000/3500) Subscribers
Topic: XTS3000 strange issue: This radio is NOT FLASHportable!!
Replies: 11
Views: 7942

Re: XTS3000 strange issue: This radio is NOT FLASHportable!!

I have never component leveled the FLASH failures ....just swapped the controller.

The price of 800 XTS's is low enough such that the parts and labor to repair not worth it.
by jry
Wed Apr 28, 2021 10:38 am
Forum: ASTRO Series (Astro Saber, Spectra, XTS3000/3500) Subscribers
Topic: XTS3000 strange issue: This radio is NOT FLASHportable!!
Replies: 11
Views: 7942

Re: XTS3000 strange issue: This radio is NOT FLASHportable!!

suspect the FLASH chip died on the controller.

Get an 800 radio and use that controller.
by jry
Tue Feb 23, 2021 5:31 am
Forum: Test Equipment & RF Equipment Alignment
Topic: R2600B/SP question
Replies: 4
Views: 6197

Re: R2600B/SP question

I have seen some R26XX's with the SP designation. The last one was in actually an R2600B with standard firmware . Was tagged as an R2660 and had the internal DC power connections for option slices . I suspect it may have been a development unit as was mentioned earlier, converted to standard and sol...
by jry
Fri Feb 05, 2021 12:24 pm
Forum: ASTRO25 Series (XTS/XTL 1500/2500/5000) Subscribers
Topic: XTS 5000 Front End Filter Alignment
Replies: 3
Views: 5183

Re: XTS 5000 Front End Filter Alignment

what model do you have ? 700/800 doesn't have that alignment IIRC for one
by jry
Sat Jan 02, 2021 2:45 pm
Forum: Test Equipment & RF Equipment Alignment
Topic: IFR COM-120B Generator Programmable Attenuator
Replies: 3
Views: 5162

Re: IFR COM-120B Generator Programmable Attenuator

I would just replace the whole unit.

There are used ones available at a reasonable price.

trying to repair that unit is not something I would do unless there wasn't a supply of used ones.

New they would be a small fortune but that model is NLA as new
by jry
Tue Dec 22, 2020 12:44 pm
Forum: ASTRO25 Series (XTS/XTL 1500/2500/5000) Subscribers
Topic: O5 to O3 control head swap?
Replies: 14
Views: 13251

Re: O5 to O3 control head swap?

thought the issue was getting the O3 head to work with a remote mount XTL currently configured and working with an O5 head. my comment was that I have never had any problem plugging the O3 head directly into the TIB /radio and never had to run the control head sync to get that operational. The butto...
by jry
Tue Dec 22, 2020 7:54 am
Forum: ASTRO25 Series (XTS/XTL 1500/2500/5000) Subscribers
Topic: O5 to O3 control head swap?
Replies: 14
Views: 13251

Re: O5 to O3 control head swap?

I plug the O3's into the TIB and just use the rear accessory cable for speaker and ignition This is my bench test setup and avoids all of the addition cables and heads for an 'O" series setup. W series remote is still a pain but those are just about gone for a real install the O3 extension cabl...
by jry
Wed Nov 11, 2020 7:46 am
Forum: ASTRO25 Series (XTS/XTL 1500/2500/5000) Subscribers
Topic: XTS/XTL on 700 MHz P25 Trunking
Replies: 8
Views: 9076

Re: XTS/XTL on 700 MHz P25 Trunking

understand ...would be good to know what you find since I have run into similar issues .

Typically I have been able to brute force my way around them by the approaches you tried

I have an even worse customer base that still has XTS3000's in service and even a few Astro Spectra Plus units.
by jry
Tue Nov 10, 2020 2:39 pm
Forum: ASTRO25 Series (XTS/XTL 1500/2500/5000) Subscribers
Topic: XTS/XTL on 700 MHz P25 Trunking
Replies: 8
Views: 9076

Re: XTS/XTL on 700 MHz P25 Trunking

Sounds like a tough one.

You may want to ask over on the Communications Support forum aka the old P25 site.

There may be more expertise for this type of problem over there
by jry
Thu Sep 17, 2020 7:18 am
Forum: Test Equipment & RF Equipment Alignment
Topic: HP 8924C front panel buttons help
Replies: 14
Views: 10613

Re: HP 8924C front panel buttons help

surprised it had a bad keyboard ...fairly passive device but you may have lost the 5 volt through the cable. May have shorted and blown the trace. Like Rick I would have just swapped it though. Parts for the 8924X are plentiful right now so even though these a very repairable parts often not worth t...
by jry
Mon Aug 31, 2020 7:51 am
Forum: Test Equipment & RF Equipment Alignment
Topic: HP 8924C front panel buttons help
Replies: 14
Views: 10613

Re: HP 8924C front panel buttons help

there should only be some chokes on the filter assembly ...iyou may have lost the +5 volt to the keyboard from the processor. Sounds like the optical sensor /spinner is working but the select button is not chances are if the keyboard is almost dead than it mostly likely a bad interface chip on the p...
by jry
Sun Aug 30, 2020 12:09 pm
Forum: Test Equipment & RF Equipment Alignment
Topic: HP 8924C front panel buttons help
Replies: 14
Views: 10613

Re: HP 8924C front panel buttons help

IIRC correctly the front panel goes directly to the processor board.

On the 8924C it may get routed through a filter assembly. 25 pin D connector with some chokes for RFI ...once again going by memory.

Nothing active on the front panel ...may be your processor board and the interface IC's
by jry
Mon Jul 27, 2020 10:13 am
Forum: ASTRO25 Series (XTS/XTL 1500/2500/5000) Subscribers
Topic: Pinout Hirose to XTS
Replies: 3
Views: 7675

Re: Pinout Hirose to XTS

I think they may need to be the later version ...at least the Astro Saber needed the D version for keyload IIRC
by jry
Tue Jul 07, 2020 3:08 pm
Forum: Test Equipment & RF Equipment Alignment
Topic: IFR 1900 CSA, Factory Reset Sequence?
Replies: 3
Views: 5953

Re: IFR 1900 CSA, Factory Reset Sequence?

may have to be in the AUX screen first and then RCL MEMORY ...select option 10 Factory Defaults
by jry
Tue Jul 07, 2020 11:47 am
Forum: Test Equipment & RF Equipment Alignment
Topic: R2600B tracking generator fall off?
Replies: 3
Views: 5705

Re: R2600B tracking generator fall off?

you have to have a tracking gen with an inverted sweep option as well ...at least the way I do it
by jry
Tue Jul 07, 2020 11:16 am
Forum: Test Equipment & RF Equipment Alignment
Topic: R2600B tracking generator fall off?
Replies: 3
Views: 5705

Re: R2600B tracking generator fall off?

see this all the time.
unit needs to be re-cal'd... there are multiple filters that need to be aligned ...real PITA part of the R26XX calibration
by jry
Sat Jul 04, 2020 4:53 am
Forum: Test Equipment & RF Equipment Alignment
Topic: IFR 1900 upside down display
Replies: 10
Views: 8921

Re: IFR 1900 upside down display

make sue the eraser is new ...never been used and be careful.
usually clean the contacts with alcohol ( 99%) or contact cleaner
by jry
Wed Jul 01, 2020 3:52 am
Forum: Test Equipment & RF Equipment Alignment
Topic: R2600 service manual????
Replies: 26
Views: 22373

Re: R2600 service manual????

there was a procedure ...believe here on this board ...to set the CAL temperatures.

Unit keeps a cold set of CAL and a WARM set IIRC.

First step in fixing or troubleshooting any R26XX is to clear the NVRAM which forces it back through re-creating the CAL tables as well
by jry
Wed Jun 24, 2020 6:23 am
Forum: Test Equipment & RF Equipment Alignment
Topic: IFR 1900 upside down display
Replies: 10
Views: 8921

Re: IFR 1900 upside down display

usual fix is to tear apart the front panel and the TFT display to re-seat the internal connectors. I usually verify with the display outside the unit first and RTV the connectors as a final step before complete re-assembly. Same issue as the COM-120C ...uses same display. you may want to consider up...
by jry
Wed Jun 24, 2020 6:18 am
Forum: Test Equipment & RF Equipment Alignment
Topic: IFR 1900 CSA, Factory Reset Sequence?
Replies: 3
Views: 5953

Re: IFR 1900 CSA, Factory Reset Sequence?

same as the 1600 ....RCL MEMORY ...select option 10 Factory Defaults
by jry
Fri May 29, 2020 5:13 am
Forum: ASTRO25 Series (XTS/XTL 1500/2500/5000) Subscribers
Topic: Flash vs Code Plug
Replies: 3
Views: 6440

Re: Flash vs Code Plug

codeplug is a term from the good old days when we used to actually blow a PROM and physically swap the part for the frequency information in relatively dumb radios compared to today. Still refers to the customer specific information but now greatly expanded to cover much more than just frequencies a...
by jry
Wed May 27, 2020 8:28 am
Forum: Test Equipment & RF Equipment Alignment
Topic: Aeroflex (IFR) Questions
Replies: 629
Views: 295155

Re: Aeroflex (IFR) Questions

just a quick follow on comment. The files used in a standard update were not enough to recover this problem ...standard update process would not fix the issues. The flash had become so corrupt that the the internal file system had to essentially be re-formatted before the update could be completed. ...

Go to advanced search