Post by dougb »

I have two MTR2000's UHF repeaters located at a 9000 foot mountain top. The site is solar power only. With the wx in Southern California we have had two total power failures at the site. The power comes back up slowly and the repeaters do not come out of the diagnostic startup modes. I have to go to the site remove power, wait 30 seconds, and plug them back in before they work again (giant pain, helicopter ride and all). Does anyone know how to bypass the diagnostic mode?

Thanks.
doug
User avatar
wavetar
Administrator
Posts: 7341
Joined: Sun Sep 09, 2001 4:00 pm

Post by wavetar »

I think it might be easier for you to find a product that'll wait a moment or two before applying full A/C power to the repeaters, rather than skipping the diagnostic mode...which I don't think you can.

Todd
No trees were harmed in the posting of this message...however an extraordinarily large number of electrons were horribly inconvenienced.

Welcome to the /\/\achine.
dougb
Posts: 4
Joined: Thu Mar 13, 2003 11:57 am

Post by dougb »

Repeaters on running on 12v buss from the solar panels.
doug
User avatar
MSS-Dave
Posts: 770
Joined: Mon Jun 30, 2003 6:02 pm
What radios do you own?: Harris XL200M. XPR7550E, NX300

Post by MSS-Dave »

dougb wrote:Repeaters on running on 12v buss from the solar panels.
Newmar makes a line of low voltage disconnects for 12 and 24 volts. Hook one of these up, it will disconnect the supply from the station at your set low voltage point and reconnect when voltage returns to at least your set point. Tessco number is 67608. I just happen to have one on the shelf here. Handles 30 amps. I don't have the 24 volt model but I do know it handles 20 amps.

You have any back up capability like a extra battery stack? You could have a primary stack for every day and a backup when the primary fails. It's probably not a option if your primary charging source is solar.

Good Luck!