Anyone familiar with the Harris Digital VersaT1lity Microwave system, items such as the DVA, DVM, MUX, ect....
I have been sent to clear some alarms that keep re-occuring such as an RCS alarm...
I am having some other alarm issues..
If someone can email me or PM me so we can share some notes or something I would greatly appreciate it..
Thanks,
-Nick
It looks like this:
<img src="http://kuhnelectronics.photosite.com/~p ... 950000.jpg">
--
<img src="http://kuhnelectronics.photosite.com/~p ... 938000.jpg">
--
<img src="http://kuhnelectronics.photosite.com/~p ... 930000.jpg">
--
<img src="http://kuhnelectronics.photosite.com/~p ... 022000.jpg">
--
<img src="http://kuhnelectronics.photosite.com/~p ... 032000.jpg">
Harris Microwave - Digital VersaT1lity
Moderator: Queue Moderator
-
- NOT ALLOWED TO BUY/SELL/TRADE
- Posts: 255
- Joined: Mon Sep 06, 2004 11:27 am
- What radios do you own?: Moto, Vertex
Harris Microwave - Digital VersaT1lity
Nick Kuhn - Communications Technician/Technical Manager
AMP Electronics - Chillicothe, OH
http://www.amp-electronics.net
AMP Electronics - Chillicothe, OH
http://www.amp-electronics.net
-
- NOT ALLOWED TO BUY/SELL/TRADE
- Posts: 255
- Joined: Mon Sep 06, 2004 11:27 am
- What radios do you own?: Moto, Vertex
I believe the far-end software application running is NetBoss maybe...??
Nick Kuhn - Communications Technician/Technical Manager
AMP Electronics - Chillicothe, OH
http://www.amp-electronics.net
AMP Electronics - Chillicothe, OH
http://www.amp-electronics.net
What flavour radio system is it.
It looks like a simulcast but is it part of a smartzone.
If so contact the system administartaor and find out if he has full vision and ask him to check the alarms at site xx
These alarms will give you lots of clues.
Also the programming package for the Harris sytem should also be available and this should also give detailed information on the alarms and tell you how to deal eith them.
It looks like a simulcast but is it part of a smartzone.
If so contact the system administartaor and find out if he has full vision and ask him to check the alarms at site xx
These alarms will give you lots of clues.
Also the programming package for the Harris sytem should also be available and this should also give detailed information on the alarms and tell you how to deal eith them.
-
- Posts: 161
- Joined: Tue Feb 03, 2004 12:46 pm