XTS5000 VHF Quick Call II Decode Problem

Post by DC615 »

I'm having a problem setting these up. I've created a long tone that decodes well on the National Weather Services 1050.0 Hz tone, but I can't get the two-tones to decode for my fire house. They are in a non-FPP bank. Can anyone fill me in on the steps to get these to work? Maybe someone that has one set up that can tell me the boxes they have checked. I'm very annoyed.

We use AB-AC format. Tones are input correctly.

Thanks for any help.

-Daniel
DC615
User avatar
HLA
Posts: 2334
Joined: Mon Jul 11, 2005 8:15 pm
What radios do you own?: HT1550's, X9000's, CDM1550's

Re: XTS5000 VHF Quick Call II Decode Problem

Post by HLA »

are they transmitted with or without a pl/dpl? try setting it up on csq?
HLA
I never check PM's so don't bother, just email me.
I won't reply to a hotmail, gmail, aol or any other generic free address, if you want me to reply use a real address.
STOP ASKING ME FOR SOFTWARE OR FIRMWARE, I JUST FORWARD ALL OF THE REQUESTS TO THE MODERATORS
DC615
Posts: 61
Joined: Sun Nov 27, 2005 9:48 pm
What radios do you own?: XTS5000R M3, XTVA w/HHCH

Re: XTS5000 VHF Quick Call II Decode Problem

Post by DC615 »

Yes it is transmitted with a PL. I may try the CSQ thing though. Every radio I've ever delt with has never had this problem using PL.
DC615
User avatar
The Pager Geek
Posts: 1250
Joined: Fri Jun 21, 2002 10:31 pm
What radios do you own?: Disney FRS

Re: XTS5000 VHF Quick Call II Decode Problem

Post by The Pager Geek »

DC615 wrote:I'm having a problem setting these up. I've created a long tone that decodes well on the National Weather Services 1050.0 Hz tone, but I can't get the two-tones to decode for my fire house. They are in a non-FPP bank. Can anyone fill me in on the steps to get these to work? Maybe someone that has one set up that can tell me the boxes they have checked. I'm very annoyed.

We use AB-AC format. Tones are input correctly.

Thanks for any help.

-Daniel

what's the host firmware revision of the radio?

tpg
Experienced Provider of Useless Information
DC615
Posts: 61
Joined: Sun Nov 27, 2005 9:48 pm
What radios do you own?: XTS5000R M3, XTVA w/HHCH

Re: XTS5000 VHF Quick Call II Decode Problem

Post by DC615 »

Host 11.00.01

I tested it on a off channel encoding with my maxtrac with success. It will not activate with my departments repeater though. I think the repeater is jacked up. They recently moved the voter to a new tower, and now were getting skips from several agencies. Then they made some adjustments to the repeater, I load the tones during all this, and walla; no decode. The maxtracs and minitors are working though, with the maxtracs missing a call here and there. The repeater is a mtr2000 i think.
DC615
Hightower
Posts: 976
Joined: Mon Sep 24, 2001 4:00 pm

Re: XTS5000 VHF Quick Call II Decode Problem

Post by Hightower »

Sounds like the deviation of the Q/C tones is too low. The XTS5000 is picky and needs a pretty hot Q/C deviation to activate. I think the Q/C deviation needs to be at or above 3K to work properly.

I can set the Q/C deviation to 1K and it triggers the uniden 396 and 996 all day long, but the 5K's needed much higher deviation to trigger.

Food for thought.....
User avatar
n7maq
Posts: 1440
Joined: Tue Nov 27, 2001 4:00 pm
What radios do you own?: Mocom 70 w/scan!!

Re: XTS5000 VHF Quick Call II Decode Problem

Post by n7maq »

Hightower wrote:Sounds like the deviation of the Q/C tones is too low. The XTS5000 is picky and needs a pretty hot Q/C deviation to activate. I think the Q/C deviation needs to be at or above 3K to work properly.

I can set the Q/C deviation to 1K and it triggers the uniden 396 and 996 all day long, but the 5K's needed much higher deviation to trigger.

Food for thought.....
Dan,

I can test this. Email me a copy of the codeplug and I will test in on the bench next week to see what level they open at.

Also are you in CSQ as asked? Some consoles strip PL when sending paging tones.


Jim
DC615
Posts: 61
Joined: Sun Nov 27, 2005 9:48 pm
What radios do you own?: XTS5000R M3, XTVA w/HHCH

Re: XTS5000 VHF Quick Call II Decode Problem

Post by DC615 »

Thanks men! Jim, its on the way to you brother. Thanks for all your help.
DC615
DC615
Posts: 61
Joined: Sun Nov 27, 2005 9:48 pm
What radios do you own?: XTS5000R M3, XTVA w/HHCH

Re: XTS5000 VHF Quick Call II Decode Problem

Post by DC615 »

Missed some fine detail in your message; yes I'm in CSQ on RX.
DC615
User avatar
Sarge, USMC
Posts: 76
Joined: Mon Jun 19, 2006 6:18 am

Re: XTS5000 VHF Quick Call II Decode Problem

Post by Sarge, USMC »

walla..........?? :lol:
voila.......... 8)
Semper Fi,

Sarge