LB HT1250 delay in opening squelch

The General forum is where users can discuss any topic regarding Motorola communications equipment - hardware, software, etc. There are also several focused forums on this board, so please take the time to ensure that your questions doesn't fall into one of those categories before posting here!

Moderator: Queue Moderator

Post Reply
User avatar
Pj
Moderator
Posts: 5147
Joined: Sun Sep 09, 2001 4:00 pm
What radios do you own?: X9000 thru APX

LB HT1250 delay in opening squelch

Post by Pj »

I have a HT1250/Lowband that seems to have a little delay in opening up the squelch (speaker). This seems to happen on PL and but not on CSQ channels, all simplex with multiple makes/models used. MDC is enabled (post PTT using the caller ID tables). Squelch is set to normal, and "Standard" for unmute. Firmware 5.08.03. HMN9052E speaker mic.

Any suggestions?

Radio was bought new, so I am thinking it may need to be adjusted slightly on a montior if anything.
Lowband radio. The original and non-complicated wide area interoperable communications system
Image
john9912
New User
Posts: 88
Joined: Fri Aug 08, 2008 9:13 am

Re: LB HT1250 delay in opening squelch

Post by john9912 »

Do you have MDC enabled on the receive signaling system side? If so, goto signaling, MDC system, open the system you are using, click on the DOS tab, change the DOS (Data Operated Squelch) auto mute duration time from the default of 500ms to disabled (0 ms).

John Liguori
All Technical Services LLC
Franklin, NJ