Removing Zetron 4010 from dispatch console

This forum is for discussions regarding System Infrastructure and Related Equipment. This includes but is not limited to repeaters, base stations, consoles, voters, Voice over IP, system design and implementation, and other related topics.

Moderator: Queue Moderator

Post Reply
NIFOG291
Posts: 47
Joined: Tue Aug 18, 2009 8:49 am
What radios do you own?: XTS 5000,XTL 5000, APX7000

Removing Zetron 4010 from dispatch console

Post by NIFOG291 »

In our dispatch center we have several mobile radios wired into a Zetron 4010. We're simplifying and we only need one radio, but we need 2 desk mics. So my question is really, how many desk mics can I hook up to the accessory port of a CDM mobile? My plan is to remove the Zetron from the work area and just have mics and a shared speaker on the desktop.
User avatar
wavetar
Administrator
Posts: 7341
Joined: Sun Sep 09, 2001 4:00 pm

Re: Removing Zetron 4010 from dispatch console

Post by wavetar »

Not sure what the practical limit might be, but 2 or 3 are no problem at all.
No trees were harmed in the posting of this message...however an extraordinarily large number of electrons were horribly inconvenienced.

Welcome to the /\/\achine.
Jim202
Posts: 3610
Joined: Sun Sep 09, 2001 4:00 pm

Re: Removing Zetron 4010 from dispatch console

Post by Jim202 »

Just make sure they are compatible with the radio. Also make sure that they don't have hot mics so that they
will pick up noise or conversations in the room when another mic is keyed.

Jim



NIFOG291 wrote:In our dispatch center we have several mobile radios wired into a Zetron 4010. We're simplifying and we only need one radio, but we need 2 desk mics. So my question is really, how many desk mics can I hook up to the accessory port of a CDM mobile? My plan is to remove the Zetron from the work area and just have mics and a shared speaker on the desktop.
User avatar
Bill_G
Posts: 3087
Joined: Thu Sep 17, 2009 5:00 am

Re: Removing Zetron 4010 from dispatch console

Post by Bill_G »

And cut the parallel mic jumpers so that one PTT doesn't light up all mics. That's always fun.
maverick15951
Posts: 21
Joined: Wed Feb 11, 2004 2:46 pm

Re: Removing Zetron 4010 from dispatch console

Post by maverick15951 »

Just wire the rear mic as one and use the front mic also... That way you dont have to monkey with messing with the radio ... those zetron 4010's are junk (just my opinion...)