CDM 1550ls+ Emergency
Moderator: Queue Moderator
-
- Posts: 52
- Joined: Thu Jan 08, 2009 9:25 pm
- What radios do you own?: HT-1550, HT-1250, CDM 1550
CDM 1550ls+ Emergency
I have been programming an CDM 1550ls+ (6an Model) and can not figure out the Emergency Button. I have it programmed under P4 Button and the radio will act like it is sending the emergency but nothing happens. I there a box in the CPS I am missing?
Re: CDM 1550ls+ Emergency
Where are you trying to send the emergency to? Console? Advanced remote? Third party box (Midian, Cimmaron, etc)?
No trees were harmed in the posting of this message...however an extraordinarily large number of electrons were horribly inconvenienced.
Welcome to the /\/\achine.
Welcome to the /\/\achine.
-
- On Moderation
- Posts: 46
- Joined: Tue Dec 18, 2012 5:43 pm
Re: CDM 1550ls+ Emergency
First thing that I thought of .......
" the radio will act like it is sending the emergency but nothing happens." I will take this to mean it is indeed keying up when P4 is pressed ? Keys, but no type of modulation ?
Make sure you have some type of TX signalling enabled like MDC .
Enable MDC signalling , give it a MDC unit number and try it.
" the radio will act like it is sending the emergency but nothing happens." I will take this to mean it is indeed keying up when P4 is pressed ? Keys, but no type of modulation ?
Make sure you have some type of TX signalling enabled like MDC .
Enable MDC signalling , give it a MDC unit number and try it.
- SteveC0625
- Posts: 469
- Joined: Sat Jan 01, 2011 9:46 am
- What radios do you own?: CDM's, CP's, CM's, and more
Re: CDM 1550ls+ Emergency
I think for Emergency to work properly on the CDM's, MDC on Rx has to be enabled as well so that the host console can transmit an ack code back to the mobile. I am sure it is needed for other mobiles or portables in the same system to receive the Emergency signal.guy being a guy wrote:First thing that I thought of .......
" the radio will act like it is sending the emergency but nothing happens." I will take this to mean it is indeed keying up when P4 is pressed ? Keys, but no type of modulation ?
Make sure you have some type of TX signalling enabled like MDC .
Enable MDC signalling , give it a MDC unit number and try it.
-
- Posts: 52
- Joined: Thu Jan 08, 2009 9:25 pm
- What radios do you own?: HT-1550, HT-1250, CDM 1550
Re: CDM 1550ls+ Emergency
Sorry it took me so long to respond. I am sending it to a MIP 5000 Console. I have it programmed and working on the HT-1250ls but not the CDMwavetar wrote:Where are you trying to send the emergency to? Console? Advanced remote? Third party box (Midian, Cimmaron, etc)?
-
- Posts: 52
- Joined: Thu Jan 08, 2009 9:25 pm
- What radios do you own?: HT-1550, HT-1250, CDM 1550
Re: CDM 1550ls+ Emergency
I got it working Thanks Guys