Search found 1055 matches
- Mon Oct 23, 2017 7:07 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Quantar Conventional to 9600 Trunking Conversion
- Replies: 16
- Views: 10570
Re: Quantar Conventional to 9600 Trunking Conversion
Looks like your SWDL erased the SCM application software prior to the upload, but it bombed the upload due to a version mismatch. I suspect you tried "load and install" and then "load" both failing and ultimately wiping both partitions. As CoM asked, can you provide: - CSS Versio...
- Wed Oct 18, 2017 9:16 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Quantar Conventional to 9600 Trunking Conversion
- Replies: 16
- Views: 10570
Re: Quantar Conventional to 9600 Trunking Conversion
1: Yes 2: Yes 3: If you are looking for a stand-alone "trunking" quantar for single site trunking? The only way to make it work with JUST a Quantar is to make it an IR and force it into Site Trunking. IE: Put the EPIC2 controller back in with IR firmware and SRAM. Even then, it won't be 96...
- Sun Sep 03, 2017 8:24 pm
- Forum: APX Series Subscribers
- Topic: XE500 Speaker Mic (PMMN4106), Revision B
- Replies: 15
- Views: 15825
Re: XE500 Speaker Mic (PMMN4106), Revision B
We just did a bunch of internal testing with the XE500 and not very impressed with the performance. The ruggedized Commander outperformed it in transmit audio quality, even in a high noise environment, without all the bells and whistles. M Which mic did you select instead of the XE500? (Model?) tpg
- Fri Oct 28, 2016 4:57 am
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Wanted: Digitac 66 Block or Part Number of Same
- Replies: 10
- Views: 4747
Re: Wanted: Digitac 66 Block or Part Number of Same
Yes it does come off.
- Thu Oct 27, 2016 5:00 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: DIU oldest firmware that supports IMBE?
- Replies: 2
- Views: 2426
- Thu Oct 27, 2016 1:21 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Wanted: Digitac 66 Block or Part Number of Same
- Replies: 10
- Views: 4747
Re: Wanted: Digitac 66 Block or Part Number of Same
That is the standard 66Block pin numbers, any block will work.
Try this: BLN1147
http://www.ebay.com/itm/Motorola-BLN114 ... SwstxU~abk
tpg
Try this: BLN1147
http://www.ebay.com/itm/Motorola-BLN114 ... SwstxU~abk
tpg
- Sun Oct 23, 2016 6:15 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Wanted: Digitac 66 Block or Part Number of Same
- Replies: 10
- Views: 4747
Re: Wanted: Digitac 66 Block or Part Number of Same
Shhh.... let the fishy come....
- Wed Oct 19, 2016 9:48 am
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Wanted: Digitac 66 Block or Part Number of Same
- Replies: 10
- Views: 4747
Re: Wanted: Digitac 66 Block or Part Number of Same
Did they go like this:
26
1
27
2
28
3
?
26
1
27
2
28
3
?
- Mon Oct 10, 2016 2:25 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Digitac Questions
- Replies: 2
- Views: 2335
Re: Digitac Questions
The beauty of the Digitac is the AGC circuits. To make a VERY long story short, as long as they are all the same... the digitac will sort it out. I use -13 from avg voice for status tone. I use a combination of telco and microwave (not ideal, but that's what it is.) The ideal way is to measure at th...
- Fri Jul 15, 2016 1:08 pm
- Forum: MotoTRBO Portables and Mobiles (3xxx/5xxx/7xxx/SL) 2.0 Series Subscribers
- Topic: xpr7550 password
- Replies: 10
- Views: 13014
Re: xpr7550 password
Mis-fire
- Wed Jul 13, 2016 4:52 pm
- Forum: MotoTRBO Portables and Mobiles (3xxx/5xxx/7xxx/SL) 2.0 Series Subscribers
- Topic: xpr7550 password
- Replies: 10
- Views: 13014
- Fri Feb 13, 2015 8:07 pm
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: IWCE 2015 in Las Vegas - March 16-20
- Replies: 16
- Views: 4218
Re: IWCE 2015 in Las Vegas - March 16-20
Ha... almost sounds like OpenSky... there's a reason why it ends in "KY"escomm wrote:It's really expensive KY to get you nice and greased up before entering CPE
- Sun Feb 08, 2015 5:52 pm
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: IWCE 2015 in Las Vegas - March 16-20
- Replies: 16
- Views: 4218
Re: IWCE 2015 in Las Vegas - March 16-20
What's blackjack?escomm wrote:Just got done registering for Motorola's dealer show and IWCE. Should be good this year. Lots of blackjack to be played, lots of vodka to be drank
tpg
- Mon Jan 26, 2015 8:36 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Centracom II BLN6654D JUMPERS
- Replies: 4
- Views: 2707
Re: Centracom II BLN6654D JUMPERS
Anything specific?
- Sat Nov 29, 2014 6:49 am
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: Clicking on Transmission
- Replies: 43
- Views: 9156
Re: Clicking on Transmission
[EDIT: Missed that it doesn't happen with PL? Only happens with just DPL? If yes, disregard below...] It's pointing towards a Receiver issue. Since it's weak-signal based (happens to radios far away) it's a small signal, it could be coming from anywhere. Any chance you have a WiFi access point near ...
- Thu Sep 25, 2014 6:18 pm
- Forum: MotoTRBO Portables and Mobiles (4xxx/6xxx) 1.0 Series Subscribers
- Topic: Cap plus trunking issue
- Replies: 19
- Views: 6650
Re: Cap plus trunking issue
2.30.20 repeater FW is still chasing IP connectivity bugs.
- Thu Aug 07, 2014 2:13 pm
- Forum: MotoTRBO Portables and Mobiles (4xxx/6xxx) 1.0 Series Subscribers
- Topic: SL7550 carry solutions
- Replies: 12
- Views: 4290
Re: SL7550 carry solutions
+1RFguy wrote:Nylon cases from Bee Cases. They have belt loop and belt clip models.
Bottom of page 7. http://www.beecase.com/uploads/dealer-catalogue.pdf
- Sun Jul 13, 2014 8:22 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: GTR Wire Line
- Replies: 10
- Views: 3744
Re: GTR Wire Line
You still incorrectly assume that I'm advocating double-terminating the darned circuit in the final stages. Thank you though, for proving my point that a bridged TIMS and a terminated TIMS will display a different level. Lastly, maybe you could learn sometime from us old-timers... like comprehendin...
- Sun Jul 13, 2014 12:24 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: GTR Wire Line
- Replies: 10
- Views: 3744
Re: GTR Wire Line
I see a slight difference in level when bridged across a console to radio circuit as opposed to console to terminated TIMS. That's typical. The termination value of the radio will vary from product to product. The TIMS termination "should" be a calibrated 600ohm termination. Radios can va...
- Sat Jul 12, 2014 9:32 am
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: GTR Wire Line
- Replies: 10
- Views: 3744
Re: GTR Wire Line
My agency typically uses -6dB for a level, unless paging is involved. Others will recommend -10dB, which I personally feel is better. I disagree with Jim that the TIMS should be used in bridge mode, however. I've seen an error as great as 1.5dB in bridged mode. I would set the equipment up while it...
- Tue Jul 08, 2014 5:47 am
- Forum: Radio Programming
- Topic: Motorola NRN 8815b pager programmer
- Replies: 4
- Views: 3092
Re: Motorola NRN 8815b pager programmer
Center Positive, I use 12vdc without issues.
- Mon May 26, 2014 4:20 am
- Forum: Radio Programming
- Topic: Motorola NRN 8815b pager programmer
- Replies: 4
- Views: 3092
Re: Motorola NRN 8815b pager programmer
The light only comes on when a pager is connected... and in the case of the minitor series... in programming mode.
tpg
tpg
- Sun Apr 20, 2014 1:20 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: MIP 5000 in Public Safety
- Replies: 43
- Views: 10945
Re: MIP 5000 in Public Safety
WRONG. You STILL need a full on Astro25 master site, even if it's a "miniaturized" version, otherwise you have no means to program the OP's, no place to store the CDM, no place to store the alias database, etc. It's an EXPENSIVE and LARGE investment to go MCC7500, even if it's just for a ...
- Sun Apr 13, 2014 10:07 am
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: MIP 5000 in Public Safety
- Replies: 43
- Views: 10945
Re: MIP 5000 in Public Safety
Maybe in the States. Here in Canada at least, we have to go through ATS for Linked Capacity Plus, and by extension, Capacity Plus since it needs to be configured as a single site LCP in order to interface through VP Gate. I can't say if IPSC needs to go through ATS, as I haven't dealt with that yet...
- Wed Apr 09, 2014 7:14 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: MIP 5000 in Public Safety
- Replies: 43
- Views: 10945
Re: MIP 5000 in Public Safety
The AVTEC pricing gets REALLY ridiculous if you can't deal with them directly, and are forced to go through the Motorola ATS (Assembled Trunked/TRBO Systems) group, as is required for any 'direct connect' MotoTRBO system...you might be able to avoid that if using Outposts only, I don't know. The on...
- Mon Apr 07, 2014 2:33 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: MIP 5000 in Public Safety
- Replies: 43
- Views: 10945
Re: MIP 5000 in Public Safety
Not to be "that guy".... but.... this should be already happening. Especially in the Public Safety arena.Bill_G wrote:On the other hand, the customer, or their IT guy, or the radio maintainer, now needs to be quite familiar with servers, networks, et al.
tpg
- Thu Feb 20, 2014 1:17 am
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Tone control Mystery Theatre
- Replies: 17
- Views: 5376
Re: Tone control Mystery Theatre
Great. Thanks. I knew I was off my game. I just spent the last four days working through the flu, but was feeling it Monday and Tuesday when I first got this tone control problem. I am pretty certain I tried turning things down, but it's worth a second look. I'm not sure turning it down will help u...
- Thu Feb 13, 2014 9:26 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Tone control Mystery Theatre
- Replies: 17
- Views: 5376
Re: Tone control Mystery Theatre
Assumptions: - If the Tone remote is set for -20LLGT: (some are -30 which makes it worse in this case) - If there is -14db line loss: The levels going INTO the 2wire circuit are: HLGT is +17 Function tone is +7 LLGT is -13 (results in a -27 on the far-end) = bad (too hot) If you can put a scope on i...
- Mon Dec 09, 2013 4:24 pm
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: Anyone doing IWCE 2014 in Vegas?
- Replies: 29
- Views: 7896
Re: Anyone doing IWCE 2014 in Vegas?
It was indeed a "sweet" time...escomm wrote: Hey that was a suite... a free suite!!
Good times had by all...
tpg
- Sat Dec 07, 2013 10:30 pm
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: Anyone doing IWCE 2014 in Vegas?
- Replies: 29
- Views: 7896
Re: Anyone doing IWCE 2014 in Vegas?
Gold Coast.... lolescomm wrote:Budget places... I recommend the business hotels near the convention center. They might cost a bit more but well worth not being on the strip and dealing with the headaches that go with it.
tpg
- Sat Nov 16, 2013 8:09 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: GAI-TRONICS ICP9000 Programing Cable
- Replies: 3
- Views: 3089
Re: GAI-TRONICS ICP9000 Programing Cable
Have a Rib? 9pin to 15pin?
Same cable...
tpg
Same cable...
tpg
- Sat Nov 16, 2013 1:57 pm
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: Motorola Flash Option 1B3
- Replies: 5
- Views: 1325
Re: Motorola Flash Option 1B3
D12 B1 Q806: ASTRO IMBE Digital Operation
D11 B2 Q52: Federal Government FPP
D11 B4 Q498: Hardware Multikey Encryption w/ OTAR
D7 B1 H35: Conventional Systems Operation
D3 B1 Q53: FCC FPP And Radio Cloning
D1 B3 Q667: ADP Software Encryption
That's it.
D11 B2 Q52: Federal Government FPP
D11 B4 Q498: Hardware Multikey Encryption w/ OTAR
D7 B1 H35: Conventional Systems Operation
D3 B1 Q53: FCC FPP And Radio Cloning
D1 B3 Q667: ADP Software Encryption
That's it.
- Sat Nov 16, 2013 1:53 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Centracom Gold Elite
- Replies: 9
- Views: 2364
Re: Centracom Gold Elite
No.
For Motorola it's an "On your honor" system with Gold Elites
The only restriction for licensing is client amounts to server OS. (Function of the OS)
tpg
For Motorola it's an "On your honor" system with Gold Elites
The only restriction for licensing is client amounts to server OS. (Function of the OS)
tpg
- Mon Oct 07, 2013 4:33 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Quantar Timeout Timer
- Replies: 6
- Views: 1571
Re: Quantar Timeout Timer
Correct on all statements.
tpg
tpg
- Mon Jun 03, 2013 6:29 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: MTR 2000
- Replies: 5
- Views: 1359
Re: MTR 2000
How do you tune a Multi-Function printer?Bill_G wrote:I'm betting the duplexer didn't get retuned.
tpg
- Mon Jun 03, 2013 6:26 pm
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: SmartNet Wave Shaper/Conditioner
- Replies: 6
- Views: 2117
Re: SmartNet Wave Shaper/Conditioner
I'll bite:
Why?
tpg
Why?
tpg
- Thu May 30, 2013 10:41 am
- Forum: MotoTRBO Portables and Mobiles (4xxx/6xxx) 1.0 Series Subscribers
- Topic: What forces XPR to narrow? Newest F/W, or CPS?
- Replies: 3
- Views: 2295
- Thu May 09, 2013 8:20 pm
- Forum: Legacy Batboard Motorola ASTRO (VSELP/IMBE/AMBE) Equipment Forum
- Topic: APX 7500 and 03 Multi Control Head
- Replies: 7
- Views: 3293
Re: APX 7500 and 03 Multi Control Head
Although it doesn't solve the OP issue... there is an updated eCat.. The APX 7500 mobile radio and the O5 control head can be configured in a multi control head configuration to support up to 4 control heads on a single transceiver. This allows control of a single APX 7500 transceiver from up to 4 d...
- Tue Apr 30, 2013 1:07 pm
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: Position Available: 2-Way Radio Tech & Order Fulfillment
- Replies: 2
- Views: 2180
Re: Position Available: 2-Way Radio Tech & Order Fulfillment
Minimum wage... IF you're legal LOL
tpg
tpg
- Wed Apr 03, 2013 10:57 am
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: DIU Power
- Replies: 2
- Views: 1130
Re: DIU Power
12VDCkc0sdu wrote:I have one of the DIUs that are in the white T5600 cases wondering what voltage it takes to power it.
thanks
- Fri Mar 15, 2013 11:14 am
- Forum: MotoTRBO Portables and Mobiles (4xxx/6xxx) 1.0 Series Subscribers
- Topic: Linked capacity Plus
- Replies: 5
- Views: 2992
Re: Linked capacity Plus
What if I have a site capacity that requires 3 talkpaths or more for voice and data?cbus wrote:just look up "HYTERA pseudo trunking", rips apart the current TRBO offering!!!!!
- Sun Feb 03, 2013 1:13 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Bidirectional Inband repeater
- Replies: 4
- Views: 1585
Re: Bidirectional Inband repeater
Yup, either get some decent antenna separation or a standard 5MHz duplexer and you should be good to go.
tpg
tpg
- Fri Jan 04, 2013 1:44 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Centracom board issue
- Replies: 9
- Views: 2106
Re: Centracom board issue
It should, its made for it...webby52 wrote:WIth the daughter board on the main board it seems the slot isnt wide enough to slide it in and not make contact with the next board.
BTW - You have a TBIM, as indicated by d119
tpg
- Fri Jan 04, 2013 1:41 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: MC2500 Program Issues
- Replies: 8
- Views: 1873
Re: MC2500 Program Issues
Hello all, Happy New Year I am trying to read and edit a mc2500 deskset. I have the software loaded, cable connected, and placed the MC in prgram mode (i think). The software states that is connected to the MC and than fails out about 30 seconds after that. I cant read or write the units. Am I miss...
- Sun Dec 23, 2012 11:16 am
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Motorola PURC 5000 350W Amplifier - Specifications?
- Replies: 6
- Views: 4360
Re: Motorola PURC 5000 350W Amplifier - Specifications?
I Gotta dig it up...
Manual # 6881067E50
tpg
Manual # 6881067E50
tpg
- Mon Dec 10, 2012 2:06 pm
- Forum: Legacy Batboard Motorola ASTRO (VSELP/IMBE/AMBE) Equipment Forum
- Topic: APX Mobile: Last channel selected per zone
- Replies: 11
- Views: 4040
Re: APX Mobile: Last channel selected per zone
W3 Dual Radio single head works good here...
tpg
tpg
- Tue Oct 30, 2012 12:52 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Harris P25 Infrastructure
- Replies: 1
- Views: 1020
Re: Harris P25 Infrastructure
If it is a P25 system (Not ProVoice or god forbid OpenSky) then yes, I know the XTL2500 will work on the system. Can't say about the kenwood.
tpg
tpg
- Fri Oct 26, 2012 3:57 pm
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: Our Recent Installs - Please Critique
- Replies: 24
- Views: 4421
Re: Our Recent Installs - Please Critique
Like I said... I'm a grounding freak. (8" minimum bend radius btw) You could use split bolts, but I've seen so many come loose over time where they just spin off by touching the side of them. The hydraulic I use is Burndy BAT 750, 12 ton "handheld" crimper. It was around $3k, but wort...
- Thu Oct 25, 2012 7:14 pm
- Forum: General Motorola Solutions & Legacy Radio Discussion
- Topic: Pending Narrowband License
- Replies: 38
- Views: 9197
Re: Pending Narrowband License
Of the licenses I've processed for various entities,
Public Safety (PW) are almost automated. 3-4 days.
Anything else (business IG, etc) are 60-90 days.
tpg
Public Safety (PW) are almost automated. 3-4 days.
Anything else (business IG, etc) are 60-90 days.
tpg
- Sat Oct 20, 2012 11:24 am
- Forum: Base Stations, Repeaters, General Infrastructure
- Topic: MDC1200 on Centracom Gold Elite
- Replies: 7
- Views: 2395
Re: MDC1200 on Centracom Gold Elite
1: You do not have to shut the CEB down. They are hot swappable. Just make sure the 6 I/O is set-up as an AUX1 configuration. (Jumpers, etc) 2&3: The B1840 equates to "Conventional Non-Signalling Resource" comprising of a BLN6654 BIM. B1824 equates to "Conventional MDC Signalling ...