Users may not create topics, posts, or private messages containing or relating to the following material (especially pertaining to Motorola copyrighted software, unless you want Motorola to come along and shut this site down):

  • Listing for sale or trade of, or links to sites offering for sale or trade of, or giving away, Radio
    Service Software (RSS) or Customer Programming Software (CPS)
  • Profanity, pornography, defamation, or slanderous remarks directed towards any individual or entity
  • Commercial advertising (except in the Batboard Vendors forum, as approved by the Admin/Mod Staff)
  • Any other items which may be deemed as offensive

If any topics, posts, or private messages containing or relating to the aforementioned material are brought to the attention of the Admin/Mod Staff, they will be deleted.

Additional FAQ items appear here in Forum Rules. Please review them for posting guidelines and further clarification.

Astro-Tac 3000 expanded mode issues

This forum is for discussions regarding System Infrastructure and Related Equipment. This includes but is not limited to repeaters, base stations, consoles, voters, Voice over IP, system design and implementation, and other related topics.

Moderator: Queue Moderator

chrislxx
New User
Posts: 1
Joined: Wed Jun 24, 2020 6:44 am

Astro-Tac 3000 expanded mode issues

Postby chrislxx » Wed Jun 24, 2020 6:47 am

After searching the internet for a Astro Tac 3000 manual I was only able to find the software manual.
In attempting to connect 2 Astro Tac 3000 comparators in the expanded mode there seems to be an issue with the secondary unit and the v.25 connections. The DIU on the Master shelf’s connectivity seems to be OK
With no connection the wireline cards do not flash that there is an error, they are setup as station internal.
When veining the status screen in the RSS with no cables plugged in the port shows Idle and HDLC address is 3F
It is believed that the thin net connection between the shelves is working as when programing the ports and the reset is requested thru the RSS both shelves reset
Here are the steps that where followed.
1) Verify proper operation of both Astro Tac 3000 comparators in “Standard” mode (conventional)
2) Connect 10 MHz reference
3) Set ip addresses to be sequential
4) Connect the thin net connection utilizing a “t” connector and terminators.
5) With the programing cable on the main Set the main (DIU) shelf to Primary (save and reset)
6) With the programing cable on the secondary 1Set the secondary shelf to Secondary 1 (save and reset)
7) Move the programming cable back to main and enable the V.24 ports on the secondary 1 (save and reset)
Please tell me what I have done wrong or left out
Thank you in advance for your help.