hello all,
I have a gp300 (p94ypc00D2__), it doesn't work well, when i turned on,the yellow light blinks in slow blink... no Bip, no RX or/and TX.
on the manual, the yellow blink is codplug error but i can read the radio code plug and write a personnal and different codeplug fine with out lost data.
Any idea what happened? Any help would be much appreciated.
thanks
Olivier
gp300 bug help
Moderator: Queue Moderator
Hi 10-95 and todd,
thanks for your answers, but,... well not good news,
I haven't testing a new rib, during my first test, i use the simplrib from G1IVG ( with max232), I read the codeplug from an good another radio (same model) and i send by clone function into the bug radio,for next time, I try to use a true Rib an RLN4008B with all full capacity batteries, peharps it will be better. i use all the time the simplrib with successfully on the same radio model.
The cpu is U401 is a 68hcb11 with internal eeprom, so it is difficulte to resoldering the eeprom and th U401 is big CMS with 64 pin...
I control all voltage on all test point on the pcb for example I see the SL point with a tension is at 12V out side of 3-10V...i haven't the test the Lock Det signal...
well I continues some another tests...
at the next time.
bye
Olivier
thanks for your answers, but,... well not good news,
I haven't testing a new rib, during my first test, i use the simplrib from G1IVG ( with max232), I read the codeplug from an good another radio (same model) and i send by clone function into the bug radio,for next time, I try to use a true Rib an RLN4008B with all full capacity batteries, peharps it will be better. i use all the time the simplrib with successfully on the same radio model.
The cpu is U401 is a 68hcb11 with internal eeprom, so it is difficulte to resoldering the eeprom and th U401 is big CMS with 64 pin...
I control all voltage on all test point on the pcb for example I see the SL point with a tension is at 12V out side of 3-10V...i haven't the test the Lock Det signal...
well I continues some another tests...
at the next time.
bye
Olivier
Best regards, 73's
Olivier from PARIS (FRANCE)
Olivier from PARIS (FRANCE)
re : bug gp300
hi all,
Yes, i think the symthe+vco is not lock because outside of the range (sl Point is not in 3-10V) but I don't know if the cpu has send control command into the symthe.
So, i try to programme some frequencies into 403-470 to know if the value at SL point is different but the radio is 438-470 and the final use is 430-440 (europ ham band)
I try in few year old to test the down limit of the vco in outside range but i not remember the light and sound alarm.
another question how the radio give infomation if one chip is dead?
73's
Olivier
Yes, i think the symthe+vco is not lock because outside of the range (sl Point is not in 3-10V) but I don't know if the cpu has send control command into the symthe.
So, i try to programme some frequencies into 403-470 to know if the value at SL point is different but the radio is 438-470 and the final use is 430-440 (europ ham band)
I try in few year old to test the down limit of the vco in outside range but i not remember the light and sound alarm.
another question how the radio give infomation if one chip is dead?
73's
Olivier