After years of good working order radio first started to drain battery and making some strange noises while turned off. Soon it could not turn on at all. after I placed board on the bench I see that radio can not shut down after turning power on off switch. Mosfet Q400 is still turned on and can be turned off only if power supply is removed from the + and - contacts. I tried to change a lot of components from the good radio one by one and problems are still here.
Board is 8415234H09.
When I say it don't want to start here are the details. There is no green led on startup check. Only short plash and no sound. All voltages seems to be present. Unswitched B and SwitchedB to regulators and 5 and 3,3 V from the regulators.
One thing that is bothering me is that there is some voltage about 1,3 to 1,9V on the pin 4 of the Q405. it comes from the BATT_CODE pin and I don't know what it does and how it comes there. On the good board of the gp340 that voltage is not present.
If someone is willing to help I can write other details. So far I tried to change these parts: Q400 Main power MOSFET. Q405 dual transistor. VR506, CR411, CR412, CR413 diodes. R414 and R415 and Q417.
I prepared one page of the service manual where these parts are located but I can not find the option for attaching this page here in this post.