I have a 100w UHF MTR2000 repeater with ac powersupply. Periodically during self test it will give powersupply fail alarm. It will also intermittently give this alarm in diag. The power supply has never failed, and the repeater has never had a problem. I have had to turn off the over air alarm beep because of this. Anyone have any ideas what might be causing this?
Joe
MTR2000 POWERSUPPLY FAILURE ALARM
Moderator: Queue Moderator
I have seen where the 28Vdc will fall below 25Vdc during station transmit, causing the boot-up testing failure & becoming highlighted in the metering screen. Have you checked it's level in the metering screen? Bad A/C possibilities aside, the P.A. is likely on it's way to failure.
Oh, I have also seen this when the original heavy gauge A/C cable was lost & someone hacked up a 'regular' cable to fit into the power supply socket.
Todd
Oh, I have also seen this when the original heavy gauge A/C cable was lost & someone hacked up a 'regular' cable to fit into the power supply socket.