Minitor V Long Tone - Can timing be modified

This forum is focused on discussing Digital and Voice paging equipment, protocol's, infrastructure, and Motorola specific hardware used. Please refrain from discussing different ways to monitor the digital paging systems due to the legalities of such.

Moderator: Queue Moderator

Post Reply
RBMTS
Posts: 70
Joined: Sat Apr 27, 2002 5:08 am

Minitor V Long Tone - Can timing be modified

Post by RBMTS »

Hello everyone. I would like to set a Minitor 5 pager to a particular group page that has a timing of only 3.7 seconds. It's too short for the standard long tone setting and the V will not alert. It's an odd timing I know, but it has been verified. Typically with some of the portable radios (like the HT1000), the long tone timing can be modified down to something like 2 seconds (as I remember) - setting the radio paging parameter to 3 seconds for the long tone works just fine. I don't see anything in the M5 software that allows such a timing change. Might anyone have any suggestions? Can the timing perhaps be modified by way of a hex edit to the code plug?

Thanks for any help.
ai4ui
was kf4pxz
Posts: 400
Joined: Mon Jan 10, 2005 5:07 pm

Re: Minitor V Long Tone - Can timing be modified

Post by ai4ui »

Set it up as an A-B with the same tone & then select the steady alert tone from the pick list, or get the console reprogrammed.

RG
Wyrd bið ful ãræd, Fate is inexorable...
RBMTS
Posts: 70
Joined: Sat Apr 27, 2002 5:08 am

Re: Minitor V Long Tone - Can timing be modified

Post by RBMTS »

Thanks - however the M5 PPS will not allow the same tone in the A & B fields (using the 114 version). Reprogramming the console is not an option since this is a area wide alert being sent out on a mutual aid channel by a local authority that we want to monitor. Any other thoughts?
ai4ui
was kf4pxz
Posts: 400
Joined: Mon Jan 10, 2005 5:07 pm

Re: Minitor V Long Tone - Can timing be modified

Post by ai4ui »

Version 1.4.0 (which you can download for free from Motorola) will give an error message about a tone frequency error but the tone will stay.


http://www.motorola.com/governmentanden ... 20_4_0.zip

Robert
Wyrd bið ful ãræd, Fate is inexorable...
User avatar
The Pager Geek
Posts: 1250
Joined: Fri Jun 21, 2002 10:31 pm
What radios do you own?: Disney FRS

Re: Minitor V Long Tone - Can timing be modified

Post by The Pager Geek »

Make your Min 5 program accept the same tone...

Open Version 1.4 in a hex editor:
Go to offset 04569B(hex) or 284315(decimal) and change the 75 to an EB

I HAVE NO IDEA if the pager will alert or not, this just lets you program in 2 tones that are less than the required 1.55% (or whatever it is) into the pager.

Good luck
tpg
Experienced Provider of Useless Information
RBMTS
Posts: 70
Joined: Sat Apr 27, 2002 5:08 am

Re: Minitor V Long Tone - Can timing be modified

Post by RBMTS »

Thanks for your help guys. Unfortunately I am still not able to get the pager to respond to this alert. It has to be a timing thing. So do you think there is anything in the codeplug itself that designates the timing on a "Group" tone, or is that built into the firmware of the pager? Modifying the Group tone timing to 3 seconds instead of 4 would work pefectly. Thanks again.