SmartRIB locks down serial bus

The General forum is where users can discuss any topic regarding Motorola communications equipment - hardware, software, etc. There are also several focused forums on this board, so please take the time to ensure that your questions doesn't fall into one of those categories before posting here!

Moderator: Queue Moderator

Post Reply
User avatar
ke4zdg
Posts: 85
Joined: Fri Jun 30, 2006 6:05 am
What radios do you own?: Spectras, Sabers, MCS/MTS2000

SmartRIB locks down serial bus

Post by ke4zdg »

Hey guys,

Someone gave me a SmartRIB that doesn't work. When I hook it to a Spectra, the radio comes on and displays FAIL 01/90. As soon as I unplug it, the error goes away. I opened the rib and found a couple shorted transistors near the DB25. I have searched and searched for a schematic to get a part number for the dead transistors. Can anybody help?

Thanks,

Jared
Jim202
Posts: 3610
Joined: Sun Sep 09, 2001 4:00 pm

Re: SmartRIB locks down serial bus

Post by Jim202 »

By any chance have you taken a look at www.batlabs.com and gone into the programming area?

Jim


ke4zdg wrote:Hey guys,

Someone gave me a SmartRIB that doesn't work. When I hook it to a Spectra, the radio comes on and displays FAIL 01/90. As soon as I unplug it, the error goes away. I opened the rib and found a couple shorted transistors near the DB25. I have searched and searched for a schematic to get a part number for the dead transistors. Can anybody help?

Thanks,

Jared
User avatar
ke4zdg
Posts: 85
Joined: Fri Jun 30, 2006 6:05 am
What radios do you own?: Spectras, Sabers, MCS/MTS2000

Re: SmartRIB locks down serial bus

Post by ke4zdg »

I have. All I found was a schematic for the RLN4008B (standard RIB). I need a schematic for a SmartRIB. Anybody got anything?
User avatar
ke4zdg
Posts: 85
Joined: Fri Jun 30, 2006 6:05 am
What radios do you own?: Spectras, Sabers, MCS/MTS2000

Re: SmartRIB locks down serial bus

Post by ke4zdg »

Bump. Anybody?
radef
New User
Posts: 24
Joined: Sat Nov 24, 2007 10:16 am

Re: SmartRIB locks down serial bus

Post by radef »

I'm running into the same problem with a VHF Spectra and SmartRIB. Have you had any luck resolving this?
User avatar
Rick Rock
Posts: 757
Joined: Wed Dec 25, 2002 10:08 am

Re: SmartRIB locks down serial bus

Post by Rick Rock »

I've had the same problem- however I found if you leave the RIB off until you power the radio on, it works fine. After you program, the same thing will happen, just switch the RIB off (once programming is complete and the radio restarts) and the radio will power up normally.
Image
The Batlounge admin
http://www.batlounge.us
radef
New User
Posts: 24
Joined: Sat Nov 24, 2007 10:16 am

Re: SmartRIB locks down serial bus

Post by radef »

After a lot of messing around...here's what I found.

There's a BIOS setting in my machine called UART Powerdown. Changing the state of this fixed my problem. Turning that feature off and on made the problem go away and come back. I have a Dell Optiplex 745 machine.

I think there are several causes of this error message in certain configurations. This (BIOS setting) is what was affecting me.
Post Reply

Return to “General Motorola Solutions & Legacy Radio Discussion”