HT1250 blows fuses

The General forum is where users can discuss any topic regarding Motorola communications equipment - hardware, software, etc. There are also several focused forums on this board, so please take the time to ensure that your questions doesn't fall into one of those categories before posting here!

Moderator: Queue Moderator

Post Reply
User avatar
arlojanis
Posts: 1055
Joined: Mon Jan 28, 2002 4:00 pm

HT1250 blows fuses

Post by arlojanis »

I have had several HT1250 both UHF and VHF to blow a fuse about once a week. I have not found a cure. Have you found a cause of intermittant fuse blowing?
"The world runs on radio."
User avatar
techtonics
Posts: 84
Joined: Wed Jun 27, 2007 4:47 am

Re: HT1250 blows fuses

Post by techtonics »

We have had kinda of a similar issue with blowing fuses and loosing TX audio due to the metal shield on the housing assembly coming loose and shorting across the board. Solution was to replace the case to allow the metal plate to seat properly.
User avatar
escomm
Queue Moderator
Posts: 5170
Joined: Fri Mar 24, 2006 8:24 pm

Re: HT1250 blows fuses

Post by escomm »

I had one I couldn't figure out for the life of me, so I sent in for a flat rate, they just swapped out the whole board. Git'er done, works for me