4 wire E&M configuration on RAD IPMUX-1E

The General forum is where users can discuss any topic regarding Motorola communications equipment - hardware, software, etc. There are also several focused forums on this board, so please take the time to ensure that your questions doesn't fall into one of those categories before posting here!

Moderator: Queue Moderator

Post Reply
aking
New User
Posts: 1
Joined: Fri Apr 02, 2010 11:49 am

4 wire E&M configuration on RAD IPMUX-1E

Post by aking »

I need to extend a 4 wire E&M circuit over ethernet. I've ordered up the IPMUX-1E to do this install. I see a few of you out there have used this as well. Does anyone have specific instructions on the IPMUX on how to configure the 4 wire E&M? Time is of the essence and as soon as I get the devices, I'll need to deploy them. Thanks.
User avatar
Bill_G
Posts: 3087
Joined: Thu Sep 17, 2009 5:00 am

Re: 4 wire E&M configuration on RAD IPMUX-1E

Post by Bill_G »

I just read the manual on CD that came with the device. You can download the manual and be prepared before it arrives.

http://www.bestdatasource.com/RAD/data_ ... manual.pdf
User avatar
d119
Posts: 3538
Joined: Tue Mar 19, 2002 4:00 pm

Re: 4 wire E&M configuration on RAD IPMUX-1E

Post by d119 »

Yeah. Log into them, point them at each other on the Ethernet, and set them to 4-wire.

Make sure one unit's clocking is set to INTERNAL, and the other to ADAPTIVE. Enable OAM signaling on both ends.

Thats it :)