PDR3500 Interface Question

The General forum is where users can discuss any topic regarding Motorola communications equipment - hardware, software, etc. There are also several focused forums on this board, so please take the time to ensure that your questions doesn't fall into one of those categories before posting here!

Moderator: Queue Moderator

Post Reply
cdalonzi
New User
Posts: 1
Joined: Wed Oct 05, 2011 2:06 pm

PDR3500 Interface Question

Post by cdalonzi »

I have a customer owned PDR3500 system that needs to connect to a TRC. We do not have the manual - what is the pinout for the TRC to connect to this unit? It is supposed to have the wireline remote board installed.

Help ASAP is appreciated.

[email protected]

Dave Alonzi
630.445.5332
turtle9832
Posts: 155
Joined: Sun Mar 14, 2010 12:26 pm

Re: PDR3500 Interface Question

Post by turtle9832 »

From the Basic Service Manual page 3-1

Table 3-1. Top Panel Wireline Port Pinouts

PIN # Wireline A Port Wireline B Port

1 Line 1+ (Input) Line 2+
2 Line 1- (Input) Line 2-
3 Line 2+ (Output) (Line 1+)**
4 Line 2- (Output) (Line 1-)**
5 No Connection No Connection
6 RDSTAT+ (AuxOut7+) +5V
7 RDSTAT- (AuxOut7+) EXT PTT+
8 EXT PTT- Ground

** Requires placement of 0 ohm resisters for R56 and R57 on backplane board