Hi, I have a PURC 5000 with the advanced control shelf, and I am trying to figure out how to bypass the PA and just run off of the IPA(driver) stage. I have seen a low power PURC that does this, but I have not seen any documentation on how to do this, or if special parts were required. Simply unplugging the small Molex connector with the alarming/metering leads shuts the station down. I am thinking that there has to be a way around this, as I'd like to use the station to drive a different PA. Any ideas?
Thanks.
PURC PA Bypass
Moderator: Queue Moderator
PURC PA Bypass
"You know, I think it was James Joyce who said that a genius makes no mistakes, that his errors are on purpose and they become the portholes of discovery, that's the kind of thing you say when you do something real stupid." Red Green
-
- Posts: 266
- Joined: Wed Apr 16, 2003 11:14 am
- What radios do you own?: X9000, HT1550XLS, MTS2000, etc
Re: PURC PA Bypass
Search the archive on the Yahoo msf5000 group. Your answer is there.
I don't remember it in detail, but it's there.
zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzleave me asleep so I don't have to listen to a bitchy liberial obnoxious wife...zzzzzzzzzzzzzzzzzgeorge
I don't remember it in detail, but it's there.
zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzleave me asleep so I don't have to listen to a bitchy liberial obnoxious wife...zzzzzzzzzzzzzzzzzgeorge
Re: PURC PA Bypass
Thanks for the suggestion, I have attempted to sign up for that group.
Re: PURC PA Bypass
My two bits worth:
To operate on the IPA, you have to in some way duplicate the signals present on the gray cable going to the amp.
The thermistor can be simulated with a resistor. The forward power could come from a watt meter element as in the MSF or a resistive divider to simulate the forward power detector voltage so that the power control circuits on the UNIBOARD can operate normally.
The low power version of the MSF has only a circulator, and watt meter detector in the module that mounts in the place of the PA. Same size as the 40W PA with out power leads.
To operate on the IPA, you have to in some way duplicate the signals present on the gray cable going to the amp.
The thermistor can be simulated with a resistor. The forward power could come from a watt meter element as in the MSF or a resistive divider to simulate the forward power detector voltage so that the power control circuits on the UNIBOARD can operate normally.
The low power version of the MSF has only a circulator, and watt meter detector in the module that mounts in the place of the PA. Same size as the 40W PA with out power leads.
Aloha, Bernie
Re: PURC PA Bypass
Hi,
I also have a PURC5000 with an advanced control shelf.
I am looking all over the place to find out how to programm the thing.
There doesn't seem much info available, do you have an idea where I might be able to get my hands on it?
It appears not to use the RSS programmer but gets it info from the front panel if the right dipswitch settings are made on the control board.
Sorry I can't help you with your problem but perhaps you can point me in the right direction...
Jake
I also have a PURC5000 with an advanced control shelf.
I am looking all over the place to find out how to programm the thing.
There doesn't seem much info available, do you have an idea where I might be able to get my hands on it?
It appears not to use the RSS programmer but gets it info from the front panel if the right dipswitch settings are made on the control board.
Sorry I can't help you with your problem but perhaps you can point me in the right direction...
Jake